Commercial Refrigeration·Port St. Lucie, Florida

Walk-In Cooler Condensing Unit Replacement at Alfonso's Pizza in Port St. Lucie

Commercial refrigeration repair in Port St. Lucie: 2R Cooling replaced a failed walk-in cooler condensing unit at Alfonso's Pizza with a Tecumseh 4,100 BTU R-404A medium-temperature unit, restoring cooler temperature from 44°F to 37°F.

Equipment
Medium-temperature walk-in cooler
Customer type
Alfonso's Pizza
Service
Walk-In Cooler Repair
Condensing unit replacement in progress on the walk-in cooler at Alfonso's Pizza in Port St. Lucie.

The complaint

Alfonso's Pizza in Port St. Lucie reported that their medium-temperature walk-in cooler was running warm. The box was holding around 44°F — above safe food-storage temperature for a working restaurant kitchen.

Diagnostic findings

  • The walk-in cooler was holding approximately 44°F instead of proper medium-temperature range.
  • Inspection traced the cooling failure to the condensing unit serving the walk-in cooler.
  • The existing condensing unit could not be returned to reliable service and required replacement.

The problem

A failed condensing unit on the walk-in cooler left the box unable to hold temperature. For a restaurant, a walk-in running at 44°F puts refrigerated inventory at risk and forces an urgent repair decision.

Corrective action

  • Performed on-site refrigeration diagnostics on the walk-in cooler system.
  • Recovered the refrigerant from the failed condensing unit.
  • Removed the failed condensing unit and set a new Tecumseh 4,100 BTU medium-temperature condensing unit.
  • Reconnected the system and charged it with R-404A refrigerant.
  • Started the system and verified operation and refrigerant condition.
  • Measured final compressor amperage at approximately 5.5 amps.
  • Monitored box temperature pull-down to confirm the repair.

Parts & equipment used

  • Tecumseh 4,100 BTU medium-temperature condensing unit
  • R-404A refrigerant

Result

With the new Tecumseh condensing unit in place, the walk-in cooler pulled down from approximately 44°F to 37°F. Final compressor amperage measured approximately 5.5 amps, and system operation and refrigerant condition were verified before the job was closed out.

Refrigeration service work underway with gauges and recovery equipment staged at the Alfonso's Pizza walk-in cooler.
Walk-in cooler holding safe temperature after the new condensing unit was started and verified.

Related services

Similar problem in Port St. Lucie?

Need commercial refrigeration service in Port St. Lucie? Call 2R Cooling or request service online.